30.07.2019,06:55:44,$HST:Application just created 30.07.2019,06:55:44,$HST:SW-version 1.23, e-Callisto 30.07.2019,06:55:44,$HST:Configurationfile read 30.07.2019,06:55:44,$HST:Switched to automatic 30.07.2019,06:55:44,$HST:ATmega16 pre-configured 30.07.2019,06:55:44,$HST:Frequencyfile frq00255.cfg 30.07.2019,06:55:44,$HST:Callisto ready now... 30.07.2019,06:55:45,$HST:Measurement idle 30.07.2019,06:55:45,$HST:File scheduler.cfg read 30.07.2019,06:55:45,$HST:Measurement enable 30.07.2019,06:55:45,$CRX:AGC gain = 1.59V 30.07.2019,06:55:45,$CRX:Emitter BF199 = 0.13V 30.07.2019,06:55:45,$CRX:Analog Input = 9.24 30.07.2019,06:55:51,$HST:File FRQ00255.CFG read 30.07.2019,06:55:51,$HST:No calibration file found 30.07.2019,06:55:51,$HST:Plot buffer erased... 30.07.2019,06:55:51,$HST:Parametrisation RCU 30.07.2019,06:55:51,$CRX:ChargePump=On 30.07.2019,06:55:51,$HST:CD1316LV/IV detected 30.07.2019,06:55:51,$CRX:Debug=Off 30.07.2019,06:55:51,$CRX:Trigger=Soft 30.07.2019,06:55:51,$CRX:FPUcodex=2 30.07.2019,06:55:51,$CRX:GS =3385 30.07.2019,06:55:51,$CRX:GA =253 30.07.2019,06:55:51,$CRX:Delay=2msec 30.07.2019,06:55:51,$CRX:Frequency=870.0MHz 30.07.2019,06:55:51,$HST:Receiver connected 30.07.2019,06:55:51,$CRX:Sweeplength=200 30.07.2019,06:55:51,$CRX:low_band_max=171MHz 30.07.2019,06:55:51,$CRX:mid_band_max=450MHz 30.07.2019,06:55:51,$CRX:high_band_max=863MHz 30.07.2019,06:55:51,$CRX:Idle=0x 30.07.2019,06:55:51,$CRX:ChargePump=On 30.07.2019,06:55:51,$HST:CD1316LV/IV detected 30.07.2019,06:55:51,$CRX:Debug=Off 30.07.2019,06:55:51,$CRX:Trigger=Extern 30.07.2019,06:55:51,$CRX:FPUcodex=2 30.07.2019,06:55:51,$CRX:GS =3385 30.07.2019,06:55:51,$CRX:GA =624 30.07.2019,06:55:51,$CRX:Delay=2msec 30.07.2019,06:55:51,$CRX:Frequency=45.0MHz 30.07.2019,06:55:51,$HST:Receiver connected 30.07.2019,06:55:51,$CRX:Sweeplength=200 30.07.2019,06:55:51,$CRX:low_band_max=171MHz 30.07.2019,06:55:51,$CRX:mid_band_max=450MHz 30.07.2019,06:55:51,$CRX:high_band_max=863MHz 30.07.2019,06:55:51,$CRX:Idle=0x 30.07.2019,06:55:57,$HST:File FRQ00255.CFG read 30.07.2019,06:55:57,$HST:No calibration file found 30.07.2019,06:55:57,$HST:Plot buffer erased... 30.07.2019,06:55:57,$HST:Parametrisation RCU 30.07.2019,06:55:57,$CRX:ChargePump=On 30.07.2019,06:55:57,$HST:CD1316LV/IV detected 30.07.2019,06:55:57,$CRX:Debug=Off 30.07.2019,06:55:57,$CRX:Trigger=Extern 30.07.2019,06:55:57,$CRX:FPUcodex=2 30.07.2019,06:55:57,$CRX:GS =3385 30.07.2019,06:55:57,$CRX:GA =624 30.07.2019,06:55:57,$CRX:Delay=2msec 30.07.2019,06:55:57,$CRX:Frequency=45.0MHz 30.07.2019,06:55:57,$HST:Receiver connected 30.07.2019,06:55:57,$CRX:Sweeplength=200 30.07.2019,06:55:57,$CRX:low_band_max=171MHz 30.07.2019,06:55:57,$CRX:mid_band_max=450MHz 30.07.2019,06:55:57,$CRX:high_band_max=863MHz 30.07.2019,06:55:57,$CRX:Idle=0x 30.07.2019,06:55:57,$CRX:ChargePump=On 30.07.2019,06:55:57,$HST:CD1316LV/IV detected 30.07.2019,06:55:57,$CRX:Debug=Off 30.07.2019,06:55:57,$CRX:Trigger=Extern 30.07.2019,06:55:57,$CRX:FPUcodex=2 30.07.2019,06:55:57,$CRX:GS =3385 30.07.2019,06:55:57,$CRX:GA =624 30.07.2019,06:55:57,$CRX:Delay=2msec 30.07.2019,06:55:57,$CRX:Frequency=45.0MHz 30.07.2019,06:55:57,$HST:Receiver connected 30.07.2019,06:55:57,$CRX:Sweeplength=200 30.07.2019,06:55:57,$CRX:low_band_max=171MHz 30.07.2019,06:55:57,$CRX:mid_band_max=450MHz 30.07.2019,06:55:57,$CRX:high_band_max=863MHz 30.07.2019,06:55:57,$CRX:Idle=0x 30.07.2019,06:56:00,$HST:Param. RCU due to START 30.07.2019,06:56:00,$HST:Actual focuscode 02 30.07.2019,06:56:00,$HST:Enable data transfer 30.07.2019,06:56:00,$HST:Continuous measurement 30.07.2019,06:56:00,$CRX:Started 30.07.2019,06:56:00,$HST:Start new FITS-file 30.07.2019,06:56:01,$HST:Continous measurement 30.07.2019,06:56:04,$HST:scheduler.cfg watched 30.07.2019,06:56:49,$HST:XY plot selected 30.07.2019,06:56:51,$HST:XY plot hidden 30.07.2019,06:59:58,$HST:Measurement stop 30.07.2019,06:59:58,$HST:FITS #1 200rows x 949cols 30.07.2019,06:59:58,$HST:Measurement wait... 30.07.2019,06:59:58,$HST:EOT (&) detected 30.07.2019,06:59:58,$HST:Measurement halted 30.07.2019,06:59:58,$HST:Measurement stop 30.07.2019,06:59:58,$CRX:Stopped 30.07.2019,06:59:58,$HST:Measurement wait... 30.07.2019,06:59:59,$HST:Measurement halted 30.07.2019,06:59:59,$HST:Measurement idle 30.07.2019,06:59:59,$CRX:Stopped 30.07.2019,07:00:00,$HST:Measurement enable 30.07.2019,07:00:00,$CRX:AGC gain = 1.59V 30.07.2019,07:00:00,$CRX:Emitter BF199 = 0.13V 30.07.2019,07:00:00,$CRX:Analog Input = 9.24 30.07.2019,07:00:00,$HST:Autostart via scheduler 30.07.2019,07:00:00,$HST:Param. RCU due to START 30.07.2019,07:00:00,$HST:Actual focuscode 02 30.07.2019,07:00:00,$HST:Enable data transfer 30.07.2019,07:00:00,$HST:Continuous measurement 30.07.2019,07:00:00,$CRX:Started 30.07.2019,07:00:00,$HST:Start new FITS-file 30.07.2019,07:00:00,$HST:Continous measurement 30.07.2019,07:00:09,$CRX:e-Callisto ETH Zurich 30.07.2019,07:00:09,$HST:Watchdog triggered -> Reset 30.07.2019,07:00:09,$CRX:V1.5, 2006-11-04 30.07.2019,07:00:09,$CRX:ChargePump=On 30.07.2019,07:00:09,$HST:CD1316LV/IV detected 30.07.2019,07:00:09,$CRX:Debug=Off 30.07.2019,07:00:09,$CRX:Trigger=No 30.07.2019,07:00:09,$CRX:FPUcodex=0 30.07.2019,07:00:09,$CRX:GS =13 30.07.2019,07:00:09,$CRX:GA =253 30.07.2019,07:00:09,$CRX:Delay=0msec 30.07.2019,07:00:09,$CRX:Frequency=0.0MHz 30.07.2019,07:00:09,$HST:Receiver connected 30.07.2019,07:00:09,$CRX:Sweeplength=0 30.07.2019,07:00:09,$CRX:low_band_max=171MHz 30.07.2019,07:00:09,$CRX:mid_band_max=450MHz 30.07.2019,07:00:09,$CRX:high_band_max=863MHz 30.07.2019,07:00:09,$CRX:Idle=0x 30.07.2019,07:00:09,$CRX:ChargePump=On 30.07.2019,07:00:09,$HST:CD1316LV/IV detected 30.07.2019,07:00:09,$CRX:Debug=Off 30.07.2019,07:00:09,$CRX:Trigger=Extern 30.07.2019,07:00:09,$CRX:FPUcodex=0 30.07.2019,07:00:09,$CRX:GS =13 30.07.2019,07:00:09,$CRX:GA =624 30.07.2019,07:00:09,$CRX:Delay=0msec 30.07.2019,07:00:09,$CRX:Frequency=45.0MHz 30.07.2019,07:00:09,$HST:Receiver connected 30.07.2019,07:00:09,$CRX:Sweeplength=200 30.07.2019,07:00:09,$CRX:low_band_max=171MHz 30.07.2019,07:00:09,$CRX:mid_band_max=450MHz 30.07.2019,07:00:09,$CRX:high_band_max=863MHz 30.07.2019,07:00:09,$CRX:Idle=0x 30.07.2019,07:00:12,$HST:Auto stop due to data loss. 30.07.2019,07:00:12,$HST:Measurement stop 30.07.2019,07:00:12,$HST:Measurement wait... 30.07.2019,07:00:13,$HST:Measurement halted 30.07.2019,07:00:13,$HST:Measurement idle 30.07.2019,07:00:13,$CRX:Stopped 30.07.2019,07:00:13,$HST:Measurement enable 30.07.2019,07:00:13,$CRX:AGC gain = 1.58V 30.07.2019,07:00:13,$CRX:Emitter BF199 = 0.13V 30.07.2019,07:00:13,$CRX:Analog Input = 9.24 30.07.2019,07:00:15,$HST:Check RS232-connection! 30.07.2019,07:00:18,$HST:Attempting Auto-Start 30.07.2019,07:00:18,$HST:Param. RCU due to START 30.07.2019,07:00:18,$HST:Actual focuscode 02 30.07.2019,07:00:18,$HST:Enable data transfer 30.07.2019,07:00:18,$HST:Continuous measurement 30.07.2019,07:00:18,$CRX:Started 30.07.2019,07:00:18,$HST:Start new FITS-file 30.07.2019,07:00:18,$HST:Continous measurement 30.07.2019,07:01:41,$HST:XY plot selected 30.07.2019,07:02:51,$CRX:e-Callisto ETH Zurich 30.07.2019,07:02:51,$HST:Watchdog triggered -> Reset 30.07.2019,07:02:51,$CRX:V1.5, 2006-11-04 30.07.2019,07:02:52,$CRX:ChargePump=On 30.07.2019,07:02:52,$HST:CD1316LV/IV detected 30.07.2019,07:02:52,$CRX:Debug=Off 30.07.2019,07:02:52,$CRX:Trigger=No 30.07.2019,07:02:52,$CRX:FPUcodex=0 30.07.2019,07:02:52,$CRX:GS =13 30.07.2019,07:02:52,$CRX:GA =253 30.07.2019,07:02:52,$CRX:Delay=0msec 30.07.2019,07:02:52,$CRX:Frequency=0.0MHz 30.07.2019,07:02:52,$HST:Receiver connected 30.07.2019,07:02:52,$CRX:Sweeplength=0 30.07.2019,07:02:52,$CRX:low_band_max=171MHz 30.07.2019,07:02:52,$CRX:mid_band_max=450MHz 30.07.2019,07:02:52,$CRX:high_band_max=863MHz 30.07.2019,07:02:52,$CRX:Idle=0x 30.07.2019,07:02:52,$CRX:ChargePump=On 30.07.2019,07:02:52,$HST:CD1316LV/IV detected 30.07.2019,07:02:52,$CRX:Debug=Off 30.07.2019,07:02:52,$CRX:Trigger=Extern 30.07.2019,07:02:52,$CRX:FPUcodex=0 30.07.2019,07:02:52,$CRX:GS =13 30.07.2019,07:02:52,$CRX:GA =624 30.07.2019,07:02:52,$CRX:Delay=0msec 30.07.2019,07:02:52,$CRX:Frequency=45.0MHz 30.07.2019,07:02:52,$HST:Receiver connected 30.07.2019,07:02:52,$CRX:Sweeplength=200 30.07.2019,07:02:52,$CRX:low_band_max=171MHz 30.07.2019,07:02:52,$CRX:mid_band_max=450MHz 30.07.2019,07:02:52,$CRX:high_band_max=863MHz 30.07.2019,07:02:52,$CRX:Idle=0x 30.07.2019,07:02:54,$HST:Auto stop due to data loss. 30.07.2019,07:02:55,$HST:Measurement stop 30.07.2019,07:02:55,$HST:Measurement wait... 30.07.2019,07:02:56,$HST:Measurement halted 30.07.2019,07:02:56,$HST:Measurement idle 30.07.2019,07:02:56,$CRX:Stopped 30.07.2019,07:02:56,$HST:Measurement enable 30.07.2019,07:02:56,$CRX:AGC gain = 1.58V 30.07.2019,07:02:56,$CRX:Emitter BF199 = 0.13V 30.07.2019,07:02:56,$CRX:Analog Input = 9.24 30.07.2019,07:02:57,$HST:Check RS232-connection! 30.07.2019,07:03:00,$HST:Attempting Auto-Start 30.07.2019,07:03:01,$HST:Param. RCU due to START 30.07.2019,07:03:01,$HST:Actual focuscode 02 30.07.2019,07:03:01,$HST:Enable data transfer 30.07.2019,07:03:01,$HST:Continuous measurement 30.07.2019,07:03:01,$CRX:Started 30.07.2019,07:03:01,$HST:Start new FITS-file 30.07.2019,07:03:01,$HST:Continous measurement 30.07.2019,07:18:01,$HST:FITS #2 200rows x 3600cols 30.07.2019,07:33:01,$HST:FITS #3 200rows x 3600cols 30.07.2019,07:48:01,$HST:FITS #4 200rows x 3600cols 30.07.2019,08:03:01,$HST:FITS #5 200rows x 3600cols 30.07.2019,08:18:01,$HST:FITS #6 200rows x 3600cols 30.07.2019,08:33:01,$HST:FITS #7 200rows x 3600cols 30.07.2019,08:48:01,$HST:FITS #8 200rows x 3600cols 30.07.2019,09:02:28,$HST:XY plot hidden 30.07.2019,09:02:37,$HST:XYZ plot selected 30.07.2019,09:03:01,$HST:FITS #9 200rows x 3600cols 30.07.2019,09:08:48,$HST:scheduler.cfg watched 30.07.2019,09:18:01,$HST:FITS #10 200rows x 3600cols 30.07.2019,09:33:01,$HST:FITS #11 200rows x 3600cols 30.07.2019,09:48:01,$HST:FITS #12 200rows x 3600cols 30.07.2019,10:03:01,$HST:FITS #13 200rows x 3600cols 30.07.2019,10:18:01,$HST:FITS #14 200rows x 3600cols 30.07.2019,10:33:01,$HST:FITS #15 200rows x 3600cols 30.07.2019,10:48:01,$HST:FITS #16 200rows x 3600cols 30.07.2019,11:03:01,$HST:FITS #17 200rows x 3600cols 30.07.2019,11:18:01,$HST:FITS #18 200rows x 3600cols 30.07.2019,11:29:58,$HST:Measurement stop 30.07.2019,11:29:58,$HST:FITS #19 200rows x 2868cols 30.07.2019,11:29:58,$HST:Measurement wait... 30.07.2019,11:29:58,$HST:EOT (&) detected 30.07.2019,11:29:58,$HST:Measurement halted 30.07.2019,11:29:58,$HST:Measurement stop 30.07.2019,11:29:58,$CRX:Stopped 30.07.2019,11:29:58,$HST:Measurement wait... 30.07.2019,11:29:59,$HST:Measurement halted 30.07.2019,11:29:59,$HST:Measurement idle 30.07.2019,11:29:59,$CRX:Stopped 30.07.2019,11:30:00,$HST:Measurement enable 30.07.2019,11:30:00,$CRX:AGC gain = 1.59V 30.07.2019,11:30:00,$CRX:Emitter BF199 = 0.13V 30.07.2019,11:30:00,$CRX:Analog Input = 9.24 30.07.2019,11:30:00,$HST:Autostart via scheduler 30.07.2019,11:30:00,$HST:Param. RCU due to START 30.07.2019,11:30:00,$HST:Actual focuscode 02 30.07.2019,11:30:00,$HST:Enable data transfer 30.07.2019,11:30:00,$HST:Continuous measurement 30.07.2019,11:30:00,$CRX:Started 30.07.2019,11:30:00,$HST:Start new FITS-file 30.07.2019,11:30:00,$HST:Continous measurement 30.07.2019,11:45:00,$HST:FITS #20 200rows x 3600cols 30.07.2019,12:00:00,$HST:FITS #21 200rows x 3600cols 30.07.2019,12:15:00,$HST:FITS #22 200rows x 3600cols 30.07.2019,12:30:00,$HST:FITS #23 200rows x 3600cols 30.07.2019,12:45:00,$HST:FITS #24 200rows x 3600cols 30.07.2019,13:00:00,$HST:FITS #25 200rows x 3600cols 30.07.2019,13:15:00,$HST:FITS #26 200rows x 3600cols 30.07.2019,13:30:00,$HST:FITS #27 200rows x 3600cols 30.07.2019,13:45:00,$HST:FITS #28 200rows x 3600cols 30.07.2019,14:00:00,$HST:FITS #29 200rows x 3600cols 30.07.2019,14:15:00,$HST:FITS #30 200rows x 3600cols 30.07.2019,14:30:00,$HST:FITS #31 200rows x 3600cols 30.07.2019,14:45:00,$HST:FITS #32 200rows x 3600cols 30.07.2019,15:00:00,$HST:FITS #33 200rows x 3600cols 30.07.2019,15:15:00,$HST:FITS #34 200rows x 3600cols 30.07.2019,15:30:01,$HST:FITS #35 200rows x 3600cols 30.07.2019,15:45:01,$HST:FITS #36 200rows x 3600cols 30.07.2019,16:00:01,$HST:FITS #37 200rows x 3600cols 30.07.2019,16:15:01,$HST:FITS #38 200rows x 3600cols 30.07.2019,16:30:01,$HST:FITS #39 200rows x 3600cols 30.07.2019,16:45:01,$HST:FITS #40 200rows x 3600cols 30.07.2019,17:00:01,$HST:FITS #41 200rows x 3600cols 30.07.2019,17:15:01,$HST:FITS #42 200rows x 3600cols 30.07.2019,17:30:01,$HST:FITS #43 200rows x 3600cols 30.07.2019,17:45:01,$HST:FITS #44 200rows x 3600cols 30.07.2019,18:00:01,$HST:FITS #45 200rows x 3600cols 30.07.2019,18:15:01,$HST:FITS #46 200rows x 3600cols 30.07.2019,18:30:01,$HST:FITS #47 200rows x 3600cols 30.07.2019,18:44:58,$HST:Measurement stop 30.07.2019,18:44:58,$HST:FITS #48 200rows x 3586cols 30.07.2019,18:44:58,$HST:Measurement wait... 30.07.2019,18:44:58,$HST:EOT (&) detected 30.07.2019,18:44:58,$HST:Measurement halted 30.07.2019,18:44:58,$HST:Measurement stop 30.07.2019,18:44:58,$CRX:Stopped 30.07.2019,18:44:59,$HST:Measurement wait... 30.07.2019,18:44:59,$HST:Measurement halted 30.07.2019,18:45:00,$HST:Measurement idle 30.07.2019,18:45:00,$CRX:Stopped 30.07.2019,18:45:00,$HST:Measurement enable 30.07.2019,18:45:00,$CRX:AGC gain = 1.59V 30.07.2019,18:45:00,$CRX:Emitter BF199 = 0.13V 30.07.2019,18:45:00,$CRX:Analog Input = 9.24 30.07.2019,19:29:58,$HST:Measurement stop 30.07.2019,19:29:58,$HST:Measurement wait... 30.07.2019,19:29:59,$HST:Measurement halted 30.07.2019,19:29:59,$HST:Measurement idle 30.07.2019,19:29:59,$CRX:Stopped 30.07.2019,19:29:59,$HST:Measurement enable 30.07.2019,19:29:59,$CRX:AGC gain = 1.59V 30.07.2019,19:29:59,$CRX:Emitter BF199 = 0.13V 30.07.2019,19:29:59,$CRX:Analog Input = 9.24 30.07.2019,19:30:00,$HST:Radio monitoring 30.07.2019,19:30:00,$HST:Start overview... 30.07.2019,19:30:00,$HST:Wait ~45sec please! 30.07.2019,19:30:01,$HST:No more entries in scheduler. 30.07.2019,19:30:41,$HST:End spectral overview... 30.07.2019,19:30:41,$HST:Data in log-directory 31.07.2019,00:00:00,$HST:Midnight -> memo cleared 31.07.2019,00:00:00,$HST:EOF(logfile)